Hanna HI-5522-02 Professional bench top pH/ISE/EC dual channel meter with 5.5 inch colour LCD and capacitive touch keypad. Fully customisable, auto-logging, real-time graphic, auto-end point mode, Calibration Check, Ý, USP, USB, 230V

HI-5522 is an ideal research-grade instrument with large easy read graphic display and soft touch keypad.

Up to four conductivity calibration points can be used to increase measurement accuracy:

One fixed-point salinity calibration on the percent scale
Three methods for calculating seawater
Practical scale
Natural seawater scale
Percent scale

Use this quote list to submit your required products to Medline in order for a quotation.

Description

Hanna HI-5522-02 Professional bench top pH/ISE/EC dual channel meter with 5.5 inch colour LCD and capacitive touch keypad. Fully customisable, auto-logging, real-time graphic, auto-end point mode, Calibration Check, Ý, USP, USB, 230V
The HI-5522 is an ideal research-grade instrument with large easy read graphic display and soft touch keypad.
• Up to four conductivity calibration points can be used to increase measurement accuracy:
• One fixed-point salinity calibration on the percent scale
• Three methods for calculating seawater
• Practical scale
• Natural seawater scale
• Percent scale
The display can be customised and can display two channels simultaneously. Measurements are given in various modes: basic measurement, with or without GLP information, graph or logging data. Display colours are also selectable.
Up to 10 profiles (5 for each channel) can be saved and recalled for both meters eliminating the need to reconfigure each time a different electrode is used. User definable configurations include:
• Temperature compensation modes
• Temperature units
• Isopotential points for pH and ISE
Highly Customisable User Interface – Allows users to show measurements in various modes: basic measurement (with or without GLP information), real-time graphing, and logging data. Calibration stability criteria can be adjusted from fast, moderate, and accurate.
Capacitive Touch – Sensitive capacitive touch buttons allow accurate keystrokes during screen navigation. Four dedicated keys are used for routine operations – including calibration and switching measurement modes; and four virtual keys that change based on use. The button technology ensures against clogging from sample residue.

Features

Precision analysis

EC specific applications: USP <645> method; salinity in seawater; TDS

Five point pH calibration

Five point pH and ISE calibration

Multiple input channels: pH/ORP/ISE and EC/TDS/Resistivity/Salinity

User friendly

Large log memory with different logging methods

Multi-language support and contextual help through dedicated HELP key

Clear tutorial messaging on-screen – available from any mode

Capacitive touch keypad

New and improved backlit display

Specification

pH – Range -2.0 to 20.0pH; -2.00 to 20.00; -2.000 to 20.000pH
Resolution 0.1pH; 0.01pH; 0.001pH
Accuracy ±0.1pH; ±0.01pH; ±0.002pH ± 1LSD
Calibration automatic, up to five-point calibration, eight standard buffers available, and five custom buffers
Temperature Compensation automatic or manual from -20.0 to 120.0°C
mV – Range ±2000mV
Resolution 0.1mV
Accuracy ±0.2mV ±1 LSD
ISE – Range 1 x 10-6 to 9.99 x 1010 concentration
Resolution 1; 0.1; 0.01; 0.001 concentration
Accuracy ±0.5% (monovalent ions); ±1% (divalent ions)
Calibration automatic, up to five-point calibration, five fixed standard solutions available for each measurement unit, and five user defined standards
Temperature – Range -20.0 to 120.0°C
Resolution 0.1°C
Accuracy ±0.2°C (without probe)
EC – Range 0.000 to 9.999µS/cm; 10.00 to 99.99µS/cm; 100.0 to 999.9 µS/cm; 1.000 to 9.999 mS/cm; 10.00 to 99.99 mS/cm; 100.0 to 1000.0mS/cm absolute EC
Resolution 0.001µS/cm; 0.01µS/cm; 0.1 µS/cm; 0.001mS/cm; 0.01 mS/cm; 0.1 mS/cm
Accuracy ±1% of reading (±0.01µS/cm)
Cell Constant 0.0500 to 200.00
Cell Type 4 cells
Calibration automatic standard recognition, user standard single point/multi-point calibration
Calibration Reminder yes
Temperature Coefficient 0.00 to 10.00%/°C
Temperature Compensation disabled, linear and non-linear (natural water)
Reference Temperature 5.0 to 30.0°C
Profiles up to 10, 5 each channel
USP Compliant yes
TDS – Range 0.000 to 9.999ppm; 10.00 to 99.99ppm;
100.0 to 999.9ppm; 1.000 to 9.999ppt;
10.00 to 99.99ppt; 100.0 to 400.0ppt actual TDS
(with 1.00 factor)
Resolution 0.001ppm; 0. 01ppm; 0.1ppm; 0.001ppt;
0.01ppt; 0.1ppt; 0.001ppm; 0.01ppm; 0.1ppm;
0.001ppt; 0.01ppt; 0.1ppt
Accuracy ±1% of reading (±0.01ppm)
Resistivity – Range 1.0 to 99.9Ω • cm; 100 to 999Ω • cm;
1.00 to 9.99KΩ • cm; 10.0 to 99.9KΩ • cm;
100 to 999KΩ • 1.00 to 9.99MΩ •cm;
10.0 to 100.0MΩ • cm
Resolution 0.1Ω •cm; 1Ω • cm; 0.01KΩ •cm; 0.1KΩ •cm;
1KΩ • cm; 0.01MΩ • cm; 0.1MΩ • cm
Accuracy ±2% of reading (±1Ω • cm)
Salinity – Range practical scale: 0.00 to 42.00psu;
natural sea water scale: 0.00 to 80.00ppt;
percent scale: 0.0 to 400.0% NaCl
Resolution 0.01 for practical scale natural sea water scale;
0.1% for percent scale
Accuracy ±1% of reading
Calibration percent-scale one point (with HI-7037 standard)
pH electrode HI-1131B glass body pH electrode with BNC
connector and 1m cable (included)
EC Probe HI-76312 platinum, four-ring EC/TDS probe
with a 1m cable (included)
Temperature Probe HI-7662-T stainless steel temperature probe
with 1m cable (included)
Input Channel (s) 1 pH/ORP + 1 EC